Version 2.2
- ATTENTION: Several variables in BSB_LAN_config.h.default have changed their variable type, it’s probably best to re-create your BSB_LAN_config.h from scratch.
- Parameter numbers are now floating point (i.e. XXXX.Y) because some parameters contain two different kinds of information. These are now shown in decimal increments of 0.1. You can still qurey the “main” parameter via XXXX (without .Y)
- Lots of bugfixes and new data types
- Device-specific parameter lists supported
Version 2.1
- Many new parameters for LMU64
- ATTENTION: New categories for LMU64 and RVD/RVP controllers due to their different numbering schemes. Will be filled over time. PPS and sensor categories have moved up by two.
- ESP32: OTA now uses system-wide HTTP AUTH authentication credentials
- Improved built-in chart display (/DG), new configuration definement #define USE_ADVANCED_PLOT_LOG_FILE - thanks to Christian Ramharter
- Lots of bugfixes
Version 2.0
- ATTENTION: LOTS of new functionalities, some of which break compatibility with previous versions, so be careful and read all the docs if you make the upgrade!
- ATTENTION: Added and reorganized PPS parameters, almost all parameter numbers have changed!
- ATTENTION: Change of EEPROM layout will lead to loading of default values from BSB_LAN_config.h! You need to write settings to EEPROM in configuration menu again!
- ATTENTION: Folder locations and filenames have been adjusted for easier installation! If you update your installation, please take note that the configuration is now in BSB_LAN_config.h (LAN in caps), and no longer in BSB_lan_config.h (lower-caps “lan”)
- ATTENTION: HTTP-Authentication configuration has changed and now uses plain text instead of Base64 encoded strings!
- Thanks to GitHub user do13, this code now also compiles on a ESP32, tested on NodeMCU-ESP32, Olimex ESP32-POE and Olimex ESP32-EVB boards. ESP32 code uses SDK version 2.0.2, please take note when configuring Arduino IDE!
- OTA Updates now possible for ESP32-based devices
- Support for special PPS devices (based on DC225/Honeywell MCBA) added
- Webinterface allows for configuration of most settings without the need to re-flash, also split into basic and extended configuration
- Added better WiFi option for Arduinos through Jiri Bilek’s WiFiSpi library, using an ESP8266-based microcontroller like Wemos D1 mini or LoLin NodeMCU. Older WiFi-via-Serial approach no longer supported.
- Added MDNS_SUPPORT definement in config so that BSB-LAN can be discovered through mDNS
- If BSB-LAN cannot connect to WiFi on ESP32, it will set up its own access point “BSB-LAN” with password “BSB-LPB-PPS-LAN” for 30 minutes. After that, it will reboot and try to connect again.
- New MQTT functions, including allowing any parameter to be set by an MQTT message and actively query any parameter once by sending an MQTT message
- Added support for BME280 sensors
- Setting a temporary destination address for querying parameters by adding !x (where x is the destination id), e.g. /6224!10 to query the identification of the display unit
- URL commands /A, /B, /T and /JA have been removed as all sensors can now be accessed via parameter numbers 20000 and above as well as (currently) under new category K49.
- New categories added, subsequent categories have been shifted up
- HTTP Authentification now uses clear text username and password in configuration
- PPS users can now send time and day of week to heater
- Lots of new parameters added
- URL command /JR allows for querying the standard (reset) value of a parameter in JSON format
- URL command /JB allows for backing up parameters to JSON file
- New library for DHT22 should provide more reliable results
- Consolidated data and value types: New data types VT_YEAR, VT_DAYMONTH, VT_TIME as subsets of VT_DATETIME for parameters 1-3, replacing VT_SUMMERPERIOD and adjusting VT_VACATIONPROG. New value types DT_THMS for time consisting of hour:minutes:seconds
- MQTT: Use MQTTDeviceID as a client ID for the broker, still defaults to BSB-LAN. ATTENTION: Check your config if you’re broker relies on the client ID in any way for authorization etc.
Version 1.1
- ATTENTION: DHW Push (“Trinkwasser Push”) parameter had to be moved from 1601 to 1603 because 1601 has a different “official” meaning on some heaters. Please check and change your configuration if necessary
- ATTENTION: New categories added, most category numbers (using /K) will be shifted up by a few numbers.
- /JA URL command outputs average values
- Many new parameters decoded
- New parameters for device families 25, 44, 51, 59, 68, 85, 88, 90, 96, 97, 108, 134, 162, 163, 170, 195, 209, 211
- Improved mobile display of webinterface
- Added definement “BtSerial” for diverting serial output to Serial2 where a Bluetooth adapter can be connected (5V->5V, GND->GND, RX->TX2, TX->RX2). Adapter has to be in slave mode and configured to 115200 bps, 8N1.
- Lots of added Polish translations
- New data types VT_BYTE10, VT_SPF
- Bugfix for PPS bus regarding display of heating time programs
- Bugfix for MQTT
Version 1.0
- /JI URL command outputs configuration in JSON structure
- /JC URL command gets list of possible values from user-defined list of functions. Example: /JC=505,700,701,702,711,1600,1602
- Logging telegrams (log parameter 30000) now writes to separate file (journal.txt). It can be reset with /D0 (same time with datalog.txt) command and dumped with /DJ command.
- removed WIFI configuration as it is no longer applicable for the Due
- lots of new parameters for various device families
- Code optimization and restructuring, general increase of speed
- new schemativs for board layout V3
- lots of bugfixes
Version 0.44
- Added webserver functionality via SD card and various other improvements from GitHub user dukess
- Added JSON output for MQTT
- mobile friendlier web interface
- more parameters and device families
- last version completely tested on Mega 2560. Future versions may still run on the Mega, but will only be tested on the Arduino Due.
Version 0.43
- Added support for HardwareSerial (Serial1) connection of the adapter. Use RX pin 19 in bus() definition to activate. See manual/forum for hardware details.
- Added definement DebugTelnet to divert serial output to telnet client (port 23, no password) in BSB_lan_config.h
- Added possibility to control BSB-LAN (almost?) completely via USB-serial port. Most commands supported like their URL-counterparts, i.e. /
/xxx to query parameter xxx or / /N to restart Arduino. - Changed default device ID from 6 (room controller “RGT1”) to unused ID 66 (“LAN”)
- Many new parameters, please run /Q to see any possible changes for your device family and report back to us!
- Added global variables (arrays of 20 bytes) custom_floats[] and custom_longs[] for use with BSB_lan_custom.h, for example to read sensors etc. Output of these variables is done via new URL command /U
- Added device families 23 and 29 (Grünenwald heaters)
- Added device families 49, 52, 59 (Weishaupt heaters)
- Added device fmilies 91, 92, 94, 118, 133, 136, 137, 165, 184, 188 (various controllers like QAA75 or AVS37)
- Added device family 171 (Bösch wood pellet system)
- Added device family 172 (SensoTherm BLW Split B (RVS21.826F/200))
- Added device families 186 and 164 (Olymp WHS-500)
- Added device family 195 variant 2 (Thision 19 Plus / LMS14.111B109)
- Including DHT, 1Wire and burner status parameters (>20000) to MQTT
- English is now default language
- Updated various translations
- Added STL files to print a case with a 3D printer (thanks to FHEM user EPo!)
- Moved all sensors to /T , /H is now no longer used
- New virtual parameters 702/703 for Weishaupt room controller
- New virtual parameter 10003 to set outside temperature on newer systems
- Added text descriptions for error phases (6706 ff.)
- /Q is now more comprehensive
- New data types VT_CUSTOM_ENUM and VT_CUSTOM_BYTE to extract information from non-standard telegrams (such as 702/703)
- Bugfix: DHCP (ethernet) implementation
Version 0.42
- Added localization! Now you can help translate BSB-LAN into your language! Simply copy one of the language files from the localization folder (LANG_DE.h is the most complete) and translate whatever you can. Non-translated items will be displayed in German.
Attention: Language definition in BSB_lan_config.h is now #define LANG
For example: #define LANG DE - Added export to MQTT broker, use log_parameters[] in BSB_lan_config.h to define parameters and activate MQTTBrokerIP definement.
- Added support for WiFi modules such as an ESP8266 or a Wemos Mega connected to Serial3 (RX:15/TX:14) of the Arduino. The ESP8266 has to be flashed with the AT firmware from Espressif to work. Please take note that WiFi over serial is by design much slower (only 115kpbs) than “pure” TCP/IP connections.
- Added new category “34 - Konfiguration / Erweiterungsmodule”. All subsequent categories move one number up!
- Lots of new parameters coming from device family 123, please run /Q to see if some parameters also work for your heater!
- Lots of new yet unknown parameters through brute force querying :) (parameter numbers 10200 and above)
- Added further PPS-Bus commands, moved parameter numbers to 15000 and above
- Default PPS mode now “listening”. Use third parameter of bus definition to switch between listening and controlling, 1 stands for controlling, everything else for listening, i.e. BSB bus(68,67,1) sends data to the heater, BSB bus(68,67) only receives data from heater / room controller. You can switch between modes at run-time with URL command /P2,x where x is either 1 (for controlling) or not 1 (for listening only)
- Fixed bug that crashed PPS bus queries
- Stability improvements for PPS bus
- Improved graph legend when plotting several parameters
- Added JSON export; query with /JQ=a,b,c,d… or push queries to /JQ or push set commands to /JS
- Logging of MAX! parameters now possible with logging parameter 20007
- Added Waterstage WP device family (119)
- Added WHG Procon device family (195)
- Added unit to log file as well as average output
- Rewrote device matching in cmd_tbl to accomodate also device variant (Gerätevariante). Run /Q to see if transition has worked for your device!
- Added BSB_lan_custom_setup.h and BSB_lan_custom_global.h for you to add individual code (best used in conjunction with BSB_lan_custom.h)
- Marked all (known) OEM parameters with flag FL_OEM. OEM parameters are set by default as read-only. To make them writeable, change FL_OEM from 5 to 4 in BSB_lan_defs.h
- Increased performance for querying several parameters at once (similar to category query)
- Added config option to define subnet.
- /Q no longer needs #define DEBUG
- Bugfix ENUM memory adressing
- Bugfix in reset function (/N), clear EEPROM during reset with /NE
- Added favicon.ico
- Split of cmdtbl into cmdtbl1 and cmdtbl2 due to Arduino’s(?) limit of 32kB size of struct, opening up more space for new parameters.
Version 0.41
- Interim release containing all changes from 0.42 above, except locaization, i.e. all text fragments are still part of the main code.
Version 0.40 – 21.01.2018
- Implemented polling of MAX! heating thermostats, display with URL command /X. See BSB_lan_custom.h for an example to transmit average room temperature to heating system.
- Added new category "22 - Energiezähler" - please note that all subsequent categories move one up!
- New virtual parameter 1601 (manual TWW push)
- Added Fujitsu Waterstage WSYP100DG6 device family (211)
- Added CTC device family (103)
- New definement "#define TRUSTED_IP2" to grant access to a second local IP address
- Added optional definement "#define GatewayIP" in BSB_lan_config.h to enable setting router address different from x.x.x.1
- Removed parameter 10109 because it is the same as 10000
- Added function to check all known CommandIDs on your own heating system. Use /Q after enabling definement "#define DEBUG" in BSB_lan_config.h
- Added parameter numbers to category menu
- Updated analyze.sh
- hopefully fixing the memory issue
- Moved HTML strings to html_strings.h
Version 0.39 – 02.01.2018
- Implementation of PPS-Bus protocol. See /K40 for the limited commands available for this bus. Use setBusType(2) to set to PPS upon boot or /P2 to switch temporarily.
- Set GPIOs to input by using /Gxx,I
- Definement "#define CUSTOM_COMMANDS" added. Use this in your configuration to include individual code from "BSB_lan_custom.h" (needs to be created by you!) which is executed at the end of each main loop. Variables "custom_timer" and "custom_timer_compare" have been added to execute code at arbitrary intervals.
- Added LogoBloc Unit L-UB 25C device family (95)
- several new parameters added
- Bugfix for logging Brennerlaufzeit Stufe 2
Version 0.38 – 22.11.2017 ATTENTION: New BSB_lan_config.h configurations! You need to adjust your configuration when upgrading to this version!
- Webserver port is now defined in #define Port xx
- IP address is now defined in #define IPAddr 88,88,88,88 form - note the commas instead of dots!
- Special log parameters 20002 to 20006 have changed, see BSB_lan_config.h for their new meaning
- Added new virtual parameter 701 (Präsenztaste) which enters reduced temperature mode until next timed switch
- Added Brötje BOB device family (138), including many new parameters!
- Added Brötje SOB26 device family (28)
- Added Elco Aquatop 8es device family (85)
- Added Elco Thision 13 Plus device family (203)
- Added Weishaupt WTU 25-G familiy (50)
- Added output for absolute humidity (g/m3) for DHT22 sensors
- New schematics for Arduino/Raspberry board layout
- Included support for W5500 Ethernet2 shields. Activate definement ETHERNET_W5500 in BSB_lan_config.h
- Including two-stage oil furnaces BC-counters and logging - please note that logging parameters have been adjusted, see BSB_lan_config.h for new values!
- Added new options for commands /P and /S to allow specifying a different destination device during runtime
- Added new configuration definement CUSTOM_COMMANDS which includes BSB_lan_custom.h at the end of each main loop. You may use custom_timer (set to current millis()) and custom_timer_compare to execute only every x milliseconds.
- Bugfixing SD-card logging in monitor mode
- Bugfix for setting hour:time parameters via webinterface
Version 0.37 – 08.09.2017
- LPB implementation! More than 450 parameters supported! Switch temporarily between LPB and BSB with the Px command (0=BSB, 1=LPB) or use the setBusType config option to set bus-type at boot-time. Parameter numbers are the same as for BSB.
Version 0.36 – 23.08.2017
- bugfix: brought back VT_BIT list of options which were erroneously deleted :(, fixed/freed several memory issues
Version 0.35 – 25.06.2017
- new category "Sitherm Pro"; caution: category numbers all move up by one, starting from category "Wärmepumpe" (from 20 to 21) onwards.
- graph display of logging data now comes with crosshair and shows detailed values as tooltip
- improved SD-card output by factor 3 (from 16 to 45 kbps), switching SD-card library from from SD.h to SdFat.h (https://github.com/greiman/SdFat) brings another 10% performance boost
- adjusted paths and directory layout of SdFat to enable compiling from sketch directory.
- new data type vt_sint for signed int data, currently only used in some Sitherm Pro parameters
Version 0.34 – 29.05.2017
- Log data can now be displayed as graph
- Webinterface can now display and set vt_bit type parameters in human-readable form
- added KonfigRGx descriptions; caution: various sources used, no guarantee that descriptions match your individual heating system!
- vt_bit is generally read-only in the webinterface. To set, use URL command /S with decimal representation of value
- fixed a bug with vt_seconds_short5, affecting parameters 9500 and 9540.
- fixed bug regarding Fujitsu's device family (from 127 to 170)
- moved libraries from folder libraries to src so they can be included without copying them to the Arduino libraries folder
- modified DallasTemperature.h's include path for OneWire.h
Version 0.33 – 09.05.2017
- no more heating system definements anymore due to new autodetect function based on device family (parameter 6225), or set device_id variable to parameter value directly
- two more security options: TRUSTED_IP to limit access to one IP address only, and HTTP authentication with username and password
- Average values are saved on SD-card if present and LOGGER definement is activated
- deactivate logging by setting /L0=0 - this way you can enable LOGGER definement without filling up SD card but still save average values
- new error codes for THISION
- added dump of data payload on website for commands of unknown type, greyed out unsopported parameters
- enable logging of telegrams (log parameter 30000) also in monitor mode (bsb.cpp and bsb.h updated)
- time from heating system is now retreived periodically from broadcast telegrams, further reducing bus activity
- new data type vt_bit for parameters that set individual bits. Display as binary digits, setting still using decimal representation
- new data type vt_temp_short5_us for unsigned one byte temperatures divided by 2 (so far only 887 Vorlaufsoll NormAussentemp)
- new data type vt_percent5 for unsigned one byte temperatures divided by 2 (so far only 885 Pumpe-PWM Minimum)
- new data type vt_seconds_word5 for two byte seconds divided by 2 (so far only 2232, 9500 and 9540)
- new data type vt_seconds_short4 for (signed?) one byte seconds divided by 4 (so far only 2235)
- new data type vt_seconds_short5 for (signed?) one byte seconds divided by 5 (so far only 9500, 9540)
- new data type vt_speed2 for two byte rpm (so far only 7050)
- cleaned up set() function from apparent duplicate cases
- added cases for vt_temp_word, vt_seconds_word5, vt_temp_short, vt_temp_short5, vt_seconds_short4 to set() function
Version 0.32 – 18.04.2017
- lots of new parameters suppoerted
- newly designed webinterface allows control over heating system without any additional software or cryptic URL commands. URL commands of course are still available, so no need to change anything when using FHEM etc.
- German webinterface available with definement LANG_DE
- new URL-command /LB=x to log only broadcast messages (x=1) or all bus messages (x=0)
- new URL-command /X to reset the Arduino (need to enable RESET definement in BSB_lan_config.h)
- new logging parameters 20002 and 20003 for hot water loading times and cycles
- moved DS18B20 logging parameters from 20010-20019 to 20200-20299 and DHT22 logging parameters from 20020-20029 to 20100 to 20199
- moved average logging parameter from 20002 to 20004
- set numerous parameters to read-only because that's what they obviously are (K33-36)
- various bugfixes
Version 0.31 – 10.04.2017
- increased dumping of logfile by factor 5 / as long as we still have memory left, you can increase logbuflen from 100 to 1000 to increase transfer speed from approx. 16 to 18 kB/s
- adjusted burner activity monitoring based on broadcast messages for Brötje systems
- removed definement PROGNR_5895 because so far, it has only disabled an ENUM definition.
- removed definement PROGNR_6030 because double command ID could be resolved via BROETJE / non-BROETJE definements
- renamed BROETJE_SOB to BROETJE in order to allow for fine-grained distinction between different BROETJE cases (e.g. 6800ff). This means you have to activate TWO definements when using a Brötje system now: The general BROETJE as well as BROETJE_SOB or BROETJE_BSW. Have a look at your serial log for parameters 6800 to see which command IDs fit your system and activate one of both accordingly.
- changed 16-Bit addressing of flash memory to 32-Bit to address crashes due to ever growing PROGMEM tables - now we have lots of air to breathe again for new command IDs :)
- removed trailing \0 string from several ENUMs that led to wrong ENUM listings. Please keep in mind not to end ENUMs with a trailing \0 !
Version 0.30 – 22.03.2017
- Time library by Paul Stoffregen (https://github.com/PaulStoffregen/Time) is now required and included in the library folder.
- adds logging of raw telegram data to SD card with logging parameter
- Logging telegram data is affected by commands /V and /LU
- adds command /LU=x to log only known (x=0) or unknown (x=1) command IDs when logging telegram data
- removed define USE_BROADCAST, broadcast data is now always processed
- new internal functions GetDateTime, TranslateAddr, TranslateType
Version 0.29 – 07.03.2017
- adds command /C to display current configuration
- adds command /L to configure logging interval and parameters
- adds option for command /A to set 24h average parameters during runtime
- adds special parameter 20002 for logging /A command (24h averages, only makes sense for long logging intervals)
- bugfixes for logging DS18B20 sensors
Version 0.28 – 05.03.2017
- adds special parameters 20000++ for SD card logging of /B, /T and /H commands (see BSB_lan_config.h for examples)
- adds version info to BSB_LAN web interface
Version 0.27 – 01.03.2017
- adds date field to log file (requires exact time to be sent by heating system)
- /D0 recreates datalog.txt file with table header
- added "flags" field to command table structure. Currently, only FL_RONLY is supported to make a parameter read-only
- added DEFAULT_FLAG in config. Defaults to NULL, i.e. all fields are read/writeable. Setting it to FL_RONLY makes all parameters read-only, e.g. for added level of security. Individual parameters can be set to NULL/FL_RONLY to make only these parameters writable/read-only.
Version 0.26 – 27.02.2017
- added functionality for logging on micro SD card, using the slot of the w5100 Ethernet shield
- more parameters added (e.g. 8009)
Version 0.25 – 21.02.2017
- more FUJITSU parameters added
Version 0.24 – 14.02.2017
- updated README with added functions
- added German translations of FAQ and README, courtesy of Ulf Dieckmann
Version 0.23 – 12.02.2017
- minor bugfix
Version 0.22 – 07.02.2017
- more FUJITSU parameters
- (hopefully) correct implementation of VT_VOLTAGE readings
- minor bugfixes
Version 0.21 – 06.02.2017
- added numerous parameters for Fujitsu Wärmepumpe, including new #define FUJITSU directive to activate these parameters due to different parameter numbers
- minor bugfixes
Version 0.20 – 27.01.2017
- added more parameters for Feststoffkessel
- minor bugfixes
Version 0.19 – 01.01.2017
- added humidity command "H", currently for DHT22 sensors
- added 24h average command "A", define parameters in BSB_lan_config.h
- removed trailing whitespace from menu strings
- fixed command id 0x053D04A2 for THISION heaters
- included Rob Tillaart's DHT library because there are various libraries implementing the protocol and this one is used in the code for its ability to address multiple sensors with one object.
- removed /temp URL parameter as it is a duplicate of /T
- included loop to display DHT22 sensors in IPWE
- making compiling IPWE extensions optional (#define IPWE)
Version 0.18 – 22.12.2016
- split off configuration into bsb_lan_config.h
- split off command definitions into bsb_lan_defs.h
- changed GPIO return values from LOW/HIGH to 1/0
- reactivated and updated IPWE (define parameters in config)
- check for protected pins when accessing GPIO (define in config)
- added schematics and PCB files to new subfolder "schematics"
Version 0.17a – 20.12.2016
- minor errors corrected
Version 0.17 – 20.12.2016
- merged v0.16 with FHEM user miwi's changes
Version 0.16 – 20.11.2016
- removed IPWE and EthRly interface
- added GPIO interface
- merged parameters from J.Weber
- resolved duplicate command IDs
Version 0.15a – 25.07.2016
- collated the commands from a Python project and this project, merged the two versions, corrected obvious errors. Inserted hypothetical numerical values in ENUM definitions where Broetje manuals documented only the message texts.
- added information from traces in a Broetje installation with an ISR-SSR controller and a WOB 25C oil furnace.
Version 0.15 – 21.04.2016
- added Solar and Pufferspeicher from Elco Logon B & Logon B MM
Version 0.14 – 04.04.2016
- minor bugfixes for Broetje SOB
- extended broadcast handling (experimental)
Version 0.13 – 31.03.2016
- change resistor value in receiving path from 4k7 to 1k5
- added values 0x0f and 0x10 to Enum8005
- fixed strings for Zeitprogramme
- added timeout for sending a message (1 second)
- added option T for querying one wire temperature sensors in mixed querys
- added special handling for Broetje SOB
- simplified settings
Version 0.12 – 09.04.2015
- added ONEWIRE_SENSORS to ipwe
- fixed parameter decoding for ELCO Thision heating system
Version 0.11 – 07.04.2015
- fixed parameter decoding for ELCO Thision heating system
Version 0.10 – 15.03.2015
- added more parameters for ELCO Thision heating system
Version 0.9 – 09.03.2015
- added more parameters for ELCO Thision heating system
- printTelegramm returns value string for further processing
Version 0.8 – 05.03.2015
- added parameters for ELCO Thision heating system
- added IPWE extension
- minor bugfixes
Version 0.7 – 06.02.2015
- added bus monitor functionality
Version 0.6 – 02.02.2015
- renamed SoftwareSerial to BSBSoftwareSerial
- changed folder structure to enable simple build with arduino sdk
Version 0.5 – 02.02.2015
- bugfixes
- added documentation (README)
- added passkey feature
- added R feature (query reset value)
- added E feature (list enum values)
- added setter for almost all value types
- fixed indentation
- added V feature to set verbosity for serial output
- set baudrate to 115200 for serial output
- redirecting favicon request
- added some images of the BSB adapter
Version 0.1 – 21.01.2015 – initial version